Recent versions of DTC have checks for PCI host bridge device tree nodes
that are named something other than "pci" or "pcie". Fix all occurrences
of such nodes for Tegra boards to avoid potential warnings from DTC.
Signed-off-by: Thierry Reding <[email protected]>
Signed-off-by: Tom Warren <[email protected]>
reg = <0x0 0x80000000 0x0 0x80000000>;
};
- pcie-controller@01003000 {
+ pcie@1003000 {
status = "okay";
avddio-pex-supply = <&vdd_1v05>;
avdd-pex-pll-supply = <&vdd_1v05>;
reg = <0x80000000 0x80000000>;
};
- pcie-controller@01003000 {
+ pcie@1003000 {
status = "okay";
avddio-pex-supply = <&vdd_1v05_run>;
reg = <0x80000000 0x80000000>;
};
- pcie-controller@01003000 {
+ pcie@1003000 {
status = "okay";
avddio-pex-supply = <&vdd_1v05_run>;
interrupt-parent = <&lic>;
- pcie-controller@01003000 {
+ pcie@1003000 {
compatible = "nvidia,tegra124-pcie";
device_type = "pci";
reg = <0x01003000 0x00000800 /* PADS registers */
power-gpios = <&gpio_main TEGRA_MAIN_GPIO(P, 5) GPIO_ACTIVE_HIGH>;
};
- pcie-controller@10003000 {
+ pcie@10003000 {
status = "okay";
pci@1,0 {
power-gpios = <&gpio_main TEGRA_MAIN_GPIO(P, 6) GPIO_ACTIVE_HIGH>;
};
- pcie-controller@10003000 {
+ pcie@10003000 {
status = "okay";
pci@1,0 {
#interrupt-cells = <2>;
};
- pcie-controller@10003000 {
+ pcie@10003000 {
compatible = "nvidia,tegra186-pcie";
device_type = "pci";
reg = <0x0 0x10003000 0x0 0x00000800 /* PADS registers */
nvidia,sys-clock-req-active-high;
};
- pcie-controller@80003000 {
+ pcie@80003000 {
status = "okay";
avdd-pex-supply = <&pci_vdd_reg>;
spi-max-frequency = <25000000>;
};
- pcie-controller@80003000 {
+ pcie@80003000 {
status = "okay";
avdd-pex-supply = <&pci_vdd_reg>;
reset-names = "fuse";
};
- pcie-controller@80003000 {
+ pcie@80003000 {
compatible = "nvidia,tegra20-pcie";
device_type = "pci";
reg = <0x80003000 0x00000800 /* PADS registers */
reg = <0x0 0x80000000 0x0 0xc0000000>;
};
- pcie-controller@01003000 {
+ pcie@1003000 {
status = "okay";
pci@1,0 {
#address-cells = <2>;
#size-cells = <2>;
- pcie-controller@01003000 {
+ pcie@1003000 {
compatible = "nvidia,tegra210-pcie";
device_type = "pci";
reg = <0x0 0x01003000 0x0 0x00000800 /* PADS registers */
reg = <0x80000000 0x40000000>;
};
- pcie-controller@00003000 {
+ pcie@3000 {
status = "okay";
avdd-pexa-supply = <&vdd2_reg>;
vdd-pexa-supply = <&vdd2_reg>;
reg = <0x80000000 0x7ff00000>;
};
- pcie-controller@00003000 {
+ pcie@3000 {
status = "okay";
avdd-pexa-supply = <&ldo1_reg>;
reg = <0x80000000 0x40000000>;
};
- pcie-controller@00003000 {
+ pcie@3000 {
status = "okay";
/* AVDD_PEXA and VDD_PEXA inputs are grounded on Cardhu. */
compatible = "nvidia,tegra30";
interrupt-parent = <&lic>;
- pcie-controller@00003000 {
+ pcie@3000 {
compatible = "nvidia,tegra30-pcie";
device_type = "pci";
reg = <0x00003000 0x00000800 /* PADS registers */